1.1.0: default interval 8 h, minimum 1 h

A repeater's battery, temperature and noise do not change by the hour, and
every reading is airtime on a channel everyone shares. The dashboard window
follows: 24 h by default (2-3x the interval), staleness thresholds too.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
tthandClaude Opus 5.5 committed 2026-11-13 11:41:54 +01:00
1 parent 726a618483
commit e2d3c72ba2
9 files changed
+50 -38

No files matched your search

+4 -4
View File
@@ -7,7 +7,7 @@ on http://<listen>:9200/metrics: battery, temperature, noise floor, RSSI/SNR,
packet counters, airtime, uptime, TX queue.
Every reading costs airtime on a shared channel (~0.8 s per repeater on the
Czech preset), so the interval defaults to an hour and cannot go below 15 minutes.
Czech preset), so the interval defaults to 8 hours and cannot go below an hour.
How often do you really need the numbers? See
https://meshcore.repeater.cz/nastaveni/telemetrie/
@@ -33,10 +33,10 @@ import time
from dataclasses import dataclass
from typing import Any
__version__ = "1.0.1"
__version__ = "1.1.0"
MIN_INTERVAL = 900
DEFAULT_INTERVAL = 3600
MIN_INTERVAL = 3600
DEFAULT_INTERVAL = 28800
# A failed repeater is retried once after this, not after the full interval:
# a lost reply on air is common, and a repeater also drops a login whose
# timestamp is not newer than the last one from the same client (replay