Repeater (SenseCAP Solar): on a flat battery it no longer starts, it waits until the panel recharges it
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
8e6ee952bf
commit
0066d073db
3 files changed
+31
No files matched your search
@@ -170,6 +170,30 @@ a half-drained `rxlog`/`pktlog` page would otherwise wait for the next
|
||||
connection event — the bridge drains those on a 2-minute duty cycle, so a slower
|
||||
drain directly costs collected frames.
|
||||
|
||||
## A mast that runs flat (boot protection)
|
||||
|
||||
A panel that gets no direct sun in winter (remote-mast faces east, 11/2026:
|
||||
-50 mV a day from mid-November with consumption unchanged) eventually drains
|
||||
the cell. Without protection the node then browns out, and every bit of
|
||||
light restarts it on a cell that cannot hold it -- a boot loop at the edge.
|
||||
|
||||
`SenseCap_Solar_repeater` builds with `NRF52_POWER_MANAGEMENT` (upstream code,
|
||||
wired in `variants/sensecap_solar`, only the switch was off): at boot the
|
||||
node reads the battery and, below **3.3 V** (`PWRMGT_VOLTAGE_BOOTLOCK`), goes to
|
||||
SYSTEMOFF with the LPCOMP armed on the battery input; it wakes when the
|
||||
battery rises past the comparator threshold (3/8 VDD, ~3.4-3.7 V on the cell
|
||||
per `variant.h`) and boots normally. USB power skips the check.
|
||||
|
||||
What it does **not** do: switch off a running node as the battery falls --
|
||||
nothing in the firmware calls the runtime low-voltage shutdown. It protects
|
||||
the restart, not the discharge. The clock goes back to the build epoch after
|
||||
such a restart, as after any power loss (`gps duty` resyncs it, `time` sets it).
|
||||
|
||||
**Not yet verified on hardware**: the thresholds come from `variant.h`. Bench
|
||||
test with an adjustable supply on the battery terminals: boot at 3.2 V must
|
||||
stay dark, raising it to ~3.8 V must wake the node by itself; `get boot`
|
||||
then shows `RESETREAS=0x00020000` (bit 17, wake from LPCOMP).
|
||||
|
||||
## Measuring this yourself — two traps
|
||||
|
||||
1. **A solar node measured on its USB side measures the CHARGER.** With a
|
||||
|
||||
Reference in new issue