Repeater (SenseCAP Solar): on a flat battery it no longer starts, it waits until the panel recharges it

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
tthandClaude Opus 5.5 committed 2026-11-23 13:13:46 +01:00
1 parent 8e6ee952bf
commit 0066d073db
3 files changed
+31

No files matched your search

+6
View File
@@ -65,6 +65,12 @@ build_flags =
; CUSTOM (TeTeHacko): ...and off again, with the blue TX LED: a solar node in
; an enclosure blinks for no one. SenseCapSolarBoard.h.
-D SENSECAP_SOLAR_NO_LEDS=1
; CUSTOM (TeTeHacko): boot protection for a mast that runs flat in winter.
; Below PWRMGT_VOLTAGE_BOOTLOCK (3.3 V, variant.h) the node does not start but
; goes to SYSTEMOFF and the LPCOMP wakes it once the cell recovers, instead
; of a brown-out boot loop on a weak panel. variant.h and
; SenseCapSolarBoard.cpp had it all wired, only this switch was missing.
-D NRF52_POWER_MANAGEMENT
; -D MESH_PACKET_LOGGING=1
; -D MESH_DEBUG=1
build_src_filter = ${SenseCap_Solar.build_src_filter}