Merge upstream v1.17.1 (origin/main)

Small one after v1.17.0: 57 files, +825/-200, and it merged with no conflicts at
all. Unlike 1.17.0, the release tags sit directly on origin/main, so no
`-s ours` is needed for git describe to see the release.

What matters for our nodes:

* fix-rxgain-setting-post-agc-reset -- rx gain no longer resets after an AGC
  adjustment. The release notes ask repeater admins to verify radio.rxgain (and
  the new radio.fem.rxgain) after updating, so that goes on the post-flash list.
* NRF52 CC310 crypto is initialised once instead of on every call, and several
  NRF52 pin maps were corrected.
* New 'get/set radio.fem.rxgain/txgain' CLI commands (companion cannot configure
  them yet).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
tthandClaude Opus 5 committed 2026-08-15 14:13:50 +02:00
commit cb74cdee06
57 files changed
+824 -199

No files matched your search

+16
View File
@@ -326,6 +326,22 @@ in order of preference:
---
#### View or change the LoRa FEM transmit-path gain state on supported boards
**Usage:**
- `get radio.fem.txgain`
- `set radio.fem.txgain <state>`
**Parameters:**
- `state`: `on`|`off`
**Notes:**
- This controls a software-selectable external LoRa FEM transmit gain where the board supports it.
- On Station G3, remove the PA PL1 jumper to allow software control. `on` selects PA PL1 high/short and `off` selects PA PL1 low/open. The PA PL2 hardware jumper determines whether this switches between power levels 1/3 or 2/4.
- Select an operating level and SX1262 transmit power that comply with local RF limits and the Station G3 power-supply requirements.
- The setting is saved immediately, but on Station G3 the level is applied to the hardware at the start of the next transmit, so that the PA supply rail is never re-targeted while the PA is being driven. `get` reports the configured state, which may lead the hardware until the node next transmits.
---