Upstream shipped companion/repeater/room-server v1.17.0 today; its tree is
identical to origin/main, so that is what this merges. Our base was 7 Jul
(7b566670), i.e. 350 files / +11k lines of upstream behind.
Conflicts and how they were settled:
* Mesh.cpp -- upstream split the dedup into wasSeen() + explicit markSeen().
Kept BOTH: their new call pair AND our payload-length bound on the TRACE
path-hash read, which is what stops a crafted short TRACE from steering
isHashMatch() past the buffer.
* companion_radio/main.cpp -- upstream grew its own MultiSerialInterface
(BLE + USB + WiFi + Ethernet registered side by side), which is a superset
of the SerialDualInterface we backported from PR #1779. Took theirs whole;
our copy is now dead code. NOTE: envs that relied on the backport for a USB
console alongside BLE now need an explicit -D ENABLE_USB_INTERFACE.
* ui-new/UITask.cpp -- isSerialEnabled() was renamed isBluetoothEnabled()
upstream and DisplayDriver::RED became UIColor::warning_txt. Same intent
either way: no BT pin on screen while Bluetooth is off.
* EnvironmentSensorManager.cpp -- upstream fixed the millis() wrap on the GPS
update timer in the exact line our gpsDutyLoop() call sits on. Kept both,
with their wrap-safe compare.
* NRF52Board.cpp -- upstream independently arrived at the same sd_temp_get()
fix for SoftDevice-protected TEMP. Took their form, kept our comment, which
is the only place recording WHY (APP_MEMACC fault -> reboot on telemetry).
* RadioLibWrappers.{h,cpp}, simple_repeater/main.cpp -- add/add. Their
configSideDetectors()/performChannelScan()/external watchdog next to our
irqDoneMask()/probeDio1()/BLE pump/WDT feed. The repeater console keeps the
1032-byte reply buffer for paged analyzer output and now clears it, since a
static buffer would otherwise reprint the previous reply.
* .vscode/extensions.json -- deleted upstream, and it is in .gitignore; our
only change was a comment. Gone.
Built clean: Xiao_x1_rpt, Xiao_x2_cmp, Xiao_x3_obs, SenseCap_s1_rpt,
T1000E_cmp_cz. Not flashed to anything yet.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
* room server: added RegionMap, and new CommonCLI wiring, default_scope handling
* sensor: only minimal RegionMap wiring. Still needs work to handle default-scope
This change counts when readData returns an err code other than RADIOLIB_ERR_NONE. In most cases this is going to be a CRC error. This counter is exposed in the `stats-packets` command, and in the repeater stats payload (4 additional bytes to the payload, which is now 56 bytes with this change. My incompetent robot claims the total payload size is 96 bytes (unverified but probably close).
* ANON_REQ_TYPE_OWNER, firmware-ver removed (security exploit)
* ANON_REQ_TYPE_BASIC, formware-ver removed, just remote clock + some 'feature' bits
* CTL_TYPE_NODE_DISCOVER_REQ now ingored if 'repeat off' has been set
* repeater: onControlDataRecv(), now responds to new CTL_TYPE_NODE_DISCOVER_REQ (zero hop only)
* node prefs: new discovery_mod_timestamp (will be set to affect when node should respond to DISCOVERY_REQ's )