captureRx() ran calculatePacketHash() (SHA-256) on every received frame in
the logRx hot path. The mesh core already computes that SHA once per frame
in hasSeen() during routing, so the analyzer was doubling the crypto load
on the radio-shared main loop for no benefit.
Replace pkt_hash with a cheap FNV-1a over (type||payload): same purpose
(dedup / correlation across nodes running this FW), a fraction of the CPU.
RAM-only, no flash writes, still main-loop (not ISR) -- so this does not by
itself explain BLE link drops (those match the known SoftDevice/LoRa
coexistence instability the BLE watchdog already guards), but it removes
the one real RX-path cost the analyzer added.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two RAM-only, opt-in tables fed from the normal RX path and pulled out
over the text console (serial / BLE) for a BLE bridge + map to consume.
Both are compiled out unless the build sets a non-zero size; enabled on
SenseCap_Solar_repeater_ble (-D MAX_HEARD_NODES=48 -D RXLOG_SIZE=96,
~6 KB RAM).
nodes [offset] -- registry of heard REPEATERS and ROOM SERVERS (chat
clients are deliberately skipped: personal/mobile devices, privacy).
Per node: pubkey prefix, name, type, lat/lon, last SNR/RSSI, seconds
since heard, and the path the advert arrived by. Fed from onAdvertRecv
(adverts are signature-verified upstream). -> map dots + topology
edges + link quality.
rxlog [cursor] -- circular firehose of EVERY parsed frame heard, fed
from logRx() (synchronous, so SNR/RSSI belong to that frame). Per
record: monotonic seq (paging cursor), time, packet hash, header
(route|type), SNR/RSSI, hop path. -> live traffic / analyzer view.
Both replies are paged to stay within the ~160 B console reply cap and
carry a trailer (next cursor + totals) so the bridge can drain and detect
if it fell behind the ring. Reachable over serial, the PIN-paired BLE
console and the admin mesh CLI, same as `neighbors`.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
* room server: added RegionMap, and new CommonCLI wiring, default_scope handling
* sensor: only minimal RegionMap wiring. Still needs work to handle default-scope
This change counts when readData returns an err code other than RADIOLIB_ERR_NONE. In most cases this is going to be a CRC error. This counter is exposed in the `stats-packets` command, and in the repeater stats payload (4 additional bytes to the payload, which is now 56 bytes with this change. My incompetent robot claims the total payload size is 96 bytes (unverified but probably close).
* ANON_REQ_TYPE_OWNER, firmware-ver removed (security exploit)
* ANON_REQ_TYPE_BASIC, formware-ver removed, just remote clock + some 'feature' bits
* CTL_TYPE_NODE_DISCOVER_REQ now ingored if 'repeat off' has been set
* repeater: onControlDataRecv(), now responds to new CTL_TYPE_NODE_DISCOVER_REQ (zero hop only)
* node prefs: new discovery_mod_timestamp (will be set to affect when node should respond to DISCOVERY_REQ's )
- Added formatStatsReply, formatRadioStatsReply, and formatPacketStatsReply methods in MyMesh for both simple_repeater, simple_room_server, and simple_sensor.
- Updated CommonCLI to handle new stats commands.