`i2c` on a SenseCap answered `no I2C device answered; expected-empt`. The cut
is not in transport: the node emits those 37 bytes.
The expected-empty list's first entry is `"; expected-empty %02X"` -- 19 chars
plus a NUL -- assembled in a 16-byte scratch buffer. snprintf() stored 15 chars
and returned 19, the length it WANTED. Using that return as a byte count did
two things: memcpy read 20 bytes out of a 16-byte stack buffer, and the write
cursor advanced past the NUL that had actually been stored, so every following
address landed after the string terminator where nothing would ever read it.
So the list has been invisible on every board since it was added, not just this
one -- which matters, because the whole point of printing the addresses the
build expects is to tell "sensor absent" from "sensor at the wrong address".
Fixed by appending through a helper that measures the source with strlen() and
writes only whole entries, plus buffers sized for the real worst case. A host
reproduction under ASan flags the old path as a 20-byte read of a 16-byte
frame and the new one comes back clean, printing the full
`expected-empty 40 44 76`; in a buffer too small it now stops on an entry
boundary instead of mid-word.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
begin() already scans I2C before touching any sensor library, but only into a
MESH_DEBUG log nobody has on a deployed node. So "is that sensor actually there?"
was answerable only by inference from telemetry, and inference is what produced
`TELEM_INA226_ADDRESS=0x40` in our SenseCap envs: a guard against false-detecting
SHT41 at the library default 0x44, written as if an INA226 existed.
It does not. `i2c` on bench-rpt answers "no I2C device" -- the variant has a
single bus (WIRE_INTERFACES_COUNT 1) and nothing on it. That closed a whole line
of "measure the solar node with its own current sensor" work.
Output leads with what answered, then lists the table addresses that stayed
quiet, deduplicated and as bare hex: names for three entries sharing 0x76 alone
overran the 150 B mesh reply and truncated the interesting part.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Measured on a SenseCAP Solar P1-Pro: a continuously powered L76K costs 46.0 mA
(paired A/B, spread 43.7-47.5), which is more than everything else on the node
put together -- it runs at ~24 mA with GPS asleep. A mast repeater does not need
a continuous fix; it needs its volatile RTC set, or clients drop its replies.
`gps duty` powers the receiver only around a sync and cuts it in between. The
cadence matches the 30-minute re-sync MicroNMEALocationProvider already does, so
clock accuracy is unchanged while 42-45 of those 46 mA come back -- 42 even in
the pathological case where a fix never arrives.
Encoded as gps_enabled == 2 rather than a new pref, so the prefs file layout is
untouched and an older build just clamps the value.
The cadence is owned by the state machine, not by the provider's own re-arm, for
a concrete reason: with the receiver unpowered nothing feeds the parser, and
MicroNMEA keeps reporting the LAST fix as valid -- a provider-driven re-arm
would therefore set the RTC to a half-hour-old timestamp. Hence syncTime() (which
clears the parser) on every wake plus an own timer, and int32_t deltas so the
49-day millis() wrap cannot park GPS on or off forever.
Verified on hardware, both paths: with sky `duty, asleep, fix, 7 sats` (fix
taken, clock set, receiver cut); indoors `awake` for exactly 300 s and then
`asleep` with an hourly retry.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
bench-board died 29. 7. 2026 to a breadboard short that put GND on D1 (= DIO1)
and 5 V on D0. Signature: `sent 0` with tx_timeout climbing WHILE A WITNESS
HEARD THE FRAMES, plus `recv 0` at strong signal -- the radio works, the
interrupt line does not. setPacketReceivedAction() is the only thing that
ever sets STATE_INT_READY, so a dead line means nothing is ever picked up.
LORA_POLL_IRQ reads completion from the chip's IRQ status register over SPI
instead. The chip latches those events regardless of whether they are mapped
out to a DIO pin, so this bypasses the whole line and therefore works no
matter WHICH end of it broke. Rewiring DIO1 to a spare GPIO only helps if the
broken end is the MCU's input pad -- and that is the less likely end, because
grounding an input cannot damage the input, it stresses whatever drives the
net. Polling is strictly stronger: if it does not revive the node, no wire
will either. Cost is one extra SPI read per Dispatcher pass, next to the
isReceivingPacket() read already in that path.
getIrqFlags() returns the RAW chip register (SX126x bits, not RadioLib's
generic RADIOLIB_IRQ_* indices), so the mask comes from a new virtual
irqDoneMask() that only the chip-specific wrapper can fill in.
PIN_DIAG answers "which end?" without a multimeter:
- boot-time pull-up/pull-down sweep of every header pin, placed BEFORE
radio_init() because that halt()s when the radio does not answer -- so it
is the only diagnostic that still runs with the module unplugged, which is
also the only state where D1's result means anything (attached, the SX1262
drives DIO1 low and a healthy board reads 0 too). The internal pull is the
ohmmeter. It cannot see a lifted pad -- the resistor is on the die -- hence
the optional PIN_DIAG_LOOP_A/B jumper loopback, which drives from outside
and reads while pulling AGAINST the driver.
- `dio1` has the radio assert DIO1 via a 1-byte transmit and compares the
IRQ status register against the actual pin level. Where they disagree is
where the break is.
All of it is behind #ifdef; a build without the flags is unchanged.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
blink: a fixed burst is a race against walking to the bench -- 30 blinks
(~7 s) was not enough to find the board in time. `blink on` now runs until
`blink off`, with a 10-minute backstop so a node left blinking does not
quietly eat a battery. Cap on the counted form raised to 999.
txpwr: `set tx` cannot tell you whether the radio took the value. It clamps
to -9..30, saves the pref and replies "OK", but SX1262 accepts only -9..+22
and rejects the rest WITHOUT touching the PA -- so `get tx` can report a
power the radio never had. An earlier sweep here measured +2 dBm and -9 dBm
as RSSI -44.1 and -44.0 at a witness and concluded runtime tx power "does
not work"; that conclusion rested on an instrument that could not
distinguish a refused request from a link that does not care.
RadioLibWrapper::setTxPower keeps the status now (the signature stays void,
it implements an upstream callback), and `txpwr [dBm]` reports it. It
deliberately does not write the pref, so a sweep cannot leave a node booting
at some experimental power.
xiao_uf2_flash.sh: the 1200-baud touch is roughly a coin flip on this build.
Today it worked twice, then wedged x4, then wedged x1 -- and a wedged board
is gone from USB *and* BLE, does not recover on its own (waited 400 s) and
needs a physical replug. Not a "too soon after boot" effect: x1 had been up
23 minutes. Double-tap RESET into UF2 is reliable and takes seconds, so this
makes that the easy path. It refuses to act when several UF2 drives are
present rather than guessing, since they are all labelled XIAO-SENSE.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
CustomLR1110::startReceive() passed RADIOLIB_LR11X0_IRQ_PREAMBLE_DETECTED
(1<<4 = 16) as RadioLib's first argument, which is the RX *timeout*, not an
IRQ mask. At the LR11x0's 30.52us tick that armed the receiver for ~488us, so
it dropped out of RX before any packet could arrive and the node received
nothing at all -- while transmitting normally.
Symptoms on a SenseCAP T1000-E: tx_air_secs rising, rx_air_secs stuck at 0,
recv_errors 0, and the noise floor pinned at the -120 clamp because
getCurrentRSSI() never sampled a live receiver.
Pass RADIOLIB_LR11X0_RX_TIMEOUT_INF (continuous RX), which is what
LR11x0::startReceive() itself uses, keeping the PREAMBLE_DETECTED flag in the
reported IRQ flags as intended.
Introduced in 04b643b2 ("LR1110: add PREAMBLE_DETECTED to reported irq flags").
Verified on two T1000-E units: with only the repeater fixed it began receiving
(last_rssi -29, SNR 17.0) while the unfixed companion stayed deaf; fixing both
brought up the link in each direction.
If Bluefruit.begin fails, BLE OTA mode won't actually start and the board might require a reboot to reattempt.
Fixes:
- Bluefruit.begin returns false in NRF52Board.startOTAUpdate if OTA mode fails to start. User is notified of the fault through existing error message in CommonCLI and can reattempt "start ota" command.
A TX that fails to start (startTransmit error) or never completes
(send-complete IRQ lost) was released permanently — with an nRF52
SoftDevice servicing BLE connection events this silently ate ~40 % of
DIRECT-route forwards (measured A/B on mast-three: direct_rx +5 / direct_tx
+3 with an idle BLE connection, 5/5 with BLE off). Flood redundancy
masked the same loss for flood traffic.
Retry up to MESH_TX_RETRIES (3) with a short growing backoff; a
duplicate on air is harmless (hasSeen dedup). New tallies
tx_start_fail/tx_timeout in stats-packets + ERR_EVENT_TX_* flags make
this failure class visible at last.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>