# Power saving on a solar repeater — what it costs, measured Everything here was measured on the deployment hardware (SenseCAP Solar Node P1-Pro, nRF52840 + SX1262 + L76K) on 2026-08-05/06 with `tools/power_ab.py`, not taken from a datasheet. Numbers are input current on the 5 V USB side; the delta between two states is what the paired design measures, and that is what these figures are. ## The order that matters | lever | measured | verdict | |---|---|---| | **GPS running continuously** | **46.0 mA** (spread 43.7-47.5) | `gps duty` recovers 42-45 of it | | BLE advertising + Bluefruit's blinking LED | see below | defaults changed, LED off, 1 s interval | | `powersaving on` (MCU light sleep) | **~1 mA, not separable from zero** | keep it on (free), but it is not a lever | | RX duty cycle (`set radio.rxps`, from EasySkyMesh) | **~2.3 mA** at `max` (XIAO, 12. 11. 2026) | **no** on a live node: -16 % received and a TX stall on mast-three, see below | | `radio.rxgain off` | ~0.7 mA | **no** — 1-3 dB of sensitivity is what a mast node is for | | FEM LNA control | n/a | SenseCap has no FEM, only an RXEN switch | A whole node in the shipping configuration, with the battery charged and GPS duty-cycled, sits at **~24 mA**. Continuous GPS alone would nearly triple that. ## GPS is the whole game The receiver on this board draws 46 mA, and a mast repeater runs GPS for one reason only: the RTC is volatile, and a node whose clock is wrong has its replies dropped by clients. It does not need a continuous fix — it needs the clock set. GPS is no longer the *only* way to get that (since 7. 8. 2026 a node starts at its build epoch and any attached host sets it — see `docs/cli_commands.md` under `time`). A reboot still throws the clock back to the build epoch: carrying it across one in retained RAM was tried and measured not to work, because the bootloader's stack owns the top of RAM. GPS is still what makes a mast node's clock **absolutely** right months after the flash, with nobody there to set it, so this reasoning stands for anything on a mast. What changed is that a node without GPS is no longer stuck in 2024. `gps duty` (`gps_enabled == 2`, so no prefs-layout change) powers the receiver only around a sync, once a day (until 11/2026 every 30 minutes, the cadence `gps on` re-syncs at). The LF crystal is ±20 ppm plus ~40 ppm at −10 °C, so a day costs ~5 s of clock — far below what the mesh notices — and a reboot syncs at once anyway. Verified on hardware in both paths (with the old 30 min / 1 h timers): - with sky (`mast-three`): `duty, asleep, fix, 7 sats` — got a fix, set the clock, cut power to the receiver; - without (indoors, `bench-rpt`): `awake` for exactly 300 s (`GPS_DUTY_MAX_AWAKE_SECS`), then `asleep` with an hourly retry, so a blocked sky cannot turn duty mode back into "always on". Worst case (fix never obtained) still saves 42 mA; a normal 30 s fix saves 45. Going from 30 min to 24 h saves another 0.25–0.75 mA (hot vs. warm start, not measured per window), and the retry from 1 h to 6 h takes a node whose dome is under snow from 3.8 mA (300 s at 46 mA hourly) to 0.64 mA. Knobs: `GPS_DUTY_SYNC_INTERVAL_SECS` (86400), `GPS_DUTY_MAX_AWAKE_SECS` (300), `GPS_DUTY_RETRY_SECS` (21600). Upstream later (v1.18 dev, 11/2026) added its own `gps period `. It is not a replacement: a periodic acquisition has no timeout until the first fix ever, so the indoor case above would stay at 46 mA for good. `gps duty` sets the period to 0, and `gps on` / `gps off` leave duty mode. **One visible side effect:** `querySensors()` only adds the GPS channel to telemetry while the receiver is powered, so a duty-cycled node reports position in telemetry only during its sync windows (well under 1 % of the time). What a repeater *advertises* is unaffected — that comes from prefs via `set advert.loc prefs` (formerly `gps advert prefs`) — and `node_lat/lon` keep the last fix. Confirmed in the field: `mast-three`'s scrape now carries `voltage/temperature/humidity` and no `gps` field. ## BLE: two defaults that were quietly expensive - **The blinking LED.** Bluefruit drives `LED_BLUE` while advertising and holds it on while connected. On SenseCap Solar that pin is **12 — the same pin as `P_LORA_TX_LED`**, so a sealed mast node spent solar charge blinking an LED nobody can see, and the LoRa TX indicator lied as a bonus. `RPT_BLE_CONN_LED` now defaults to 0. - **The advertising rate.** Upstream leaves the slow interval at 244 units = 152.5 ms, i.e. three channels ~6.5 times a second, forever. `RPT_BLE_ADV_SLOW` now defaults to 1600 = 1 s; the first `RPT_BLE_ADV_FAST_SECS` (30) after boot or disconnect stay fast so discovery is still immediate when someone is looking. Bench boards keep both upstream behaviours (`-D RPT_BLE_CONN_LED=1`, `-D RPT_BLE_ADV_SLOW=244` in `xiao_analyzer`): on a desk the blinking LED is the "this thing is alive" indicator. `ble off` remains the big BLE lever for a deployed node, but the deployment rule stands: ship with BLE **on**, verify the node on site, and only then turn it off over the mesh — otherwise a node that does not come up has no way in. ## RX duty cycle (rxps) Ported from EasySkyMesh PowerSaving v18 behind `-D WITH_RX_POWERSAVING` (the public releases have it), SX1262 only, **off until set**. The radio listens in short windows and sleeps between them, staying awake through a packet once it hears a preamble; after three failed arms it falls back to continuous RX by itself. Commands: `docs/cli_commands.md`, `radio.rxps`. Measured 12. 11. 2026 on a XIAO nRF52840 + Wio-SX1262 (not the SenseCAP of the rest of this page), bench preset 866.5 MHz / SF8 / BW62.5, fed at 5 V through an INA226 (10 mOhm) read every 5 s; the only other load was a UC96 on the XIAO's USB port. A/B/A/B, 15 min cells, the first 2 min of each dropped: | cell | rxps | mean | median | |---|---|---|---| | 1 | off | 33.84 mA | 32.2 mA | | 2 | max | 31.31 mA | 30.5 mA | | 3 | off | 33.53 mA | 32.5 mA | | 4 | max | 31.36 mA | 30.3 mA | `max` (level 8) against the mean of its neighbours: **-2.4 / -2.2 mA**, pooled -2.35 mA (medians -1.95 mA); off vs off differs by 0.3 mA, max vs max by 0.05 mA. That is the radio's share, so it carries over to other SX1262 boards in absolute terms; the 33 mA base is this bench (meter, BLE advertising), not a node. Behind the XIAO's linear regulator the battery sees the same current: ~7-8 mW at 3.3 V. Reception: a 3-board zero-hop matrix (x1, x3, x4; rxps switched on x1 and x4, x3 the reference with rxps off; 20 rounds per phase, each link witnessed by another board), run twice -- on the development build, then repeated on the public release `v1.18.0+tth.20261112` (`ver` v1.18.0-tthd4afea1): | phase | development build | public release | together | |---|---|---|---| | rxps off | 0/120 | 1/120 | 1/240 | | `on` (level 3) | 1/120 | 2/120 | 3/240 | | `max` (level 8) | 0/120 | 0/120 | **0/240** | rxps stayed armed throughout, no error counts. Single losses happen with rxps off as well, and of the three at level 3 one was on x3, which had rxps off: the bench shows no degradation at any level. Not measured: mixed SF/preamble senders, a busy live mesh. On a mast, where 2 mA of ~24 is not the problem, leave it off. **On the live mesh it failed (mast-three, 14. 11. 2026, `max`).** Against ob1 as the reference for the hour-to-hour traffic, the node received ~16 % fewer packets (2.08 vs 2.47 per ob1 packet) with ~30 % more `recv_errors`, and within two hours of switching it on it stopped transmitting altogether: `sent` frozen, queue full (32), no `tx_start_fail`/`tx_timeout`, RX still counting -- so no adverts and no replies to an admin login, for 6+ hours. `radiostat` showed `irq=0x0014` (preamble + header valid, no RX done). `set radio.rxps off` did NOT bring TX back; a reboot did. The mechanism is not proven, and the radio silence watchdog cannot see it (it watches RX only). Do not enable rxps on a node that has to answer. ## MCU sleep `powersaving on` makes the nRF52 wait in WFE between events (it wakes on any interrupt, including LoRa DIO1). Upstream ships it **off**, and it was missing from our provisioning, so every node built from that file ran the core at 64 MHz around the clock. It is now in our provisioning file. **But it buys about 1 mA, not the 3-4 that seemed obvious.** Measured with GPS held off so its sync windows could not pollute the cells: paired estimate -0.96 mA over three pairs, spread -1.97 to +0.07, against a measured cell-to-cell repeatability of 1.16 mA — i.e. the effect is the same size as this rig's noise and cannot be told from zero. That fits the mechanism: the loop still polls the SX1262 over SPI on every pass and the SoftDevice wakes the core for each advertising event, so there is not much idle left to sleep through. Keep it on (it is free and cannot hurt), but do not budget for it. Blocking the loop task instead of waiting for an event (so that FreeRTOS can sleep tickless) changes nothing either: `delay(10)` against `sd_app_evt_wait()`, XIAO x4, A/B/A/B 30 min cells (14. 11. 2026): paired difference **0.04 mA**, cell repeatability 0.1-0.4 mA. The tick wakeups are not where the current goes. One fork-specific fix goes with it: the sleep is also held off while the BLE console still has queued output (`bleTxPending()`), because on the observer node a half-drained `rxlog`/`pktlog` page would otherwise wait for the next connection event — the bridge drains those on a 2-minute duty cycle, so a slower drain directly costs collected frames. ## Measuring this yourself — two traps 1. **A solar node measured on its USB side measures the CHARGER.** With a charging cell the meter reads 500-700 mA, pulsing, and the node's own tens of mA ride on top of a drifting number. Wait for the charge to finish (it fell 0.71 → 0.53 → 0.22 → 0.05 A over about an hour here) or the numbers are fiction. There is **no INA226 on this board** to cross-check with — the `i2c` command reports nothing at all on the only bus the variant has — on three separate P1-Pro units (`bench-rpt`, `mast-rpt-two`, `tth-mast-repeater-one`), against a sensor table that expects `38 76 70 44 5C 42 40 41 5A 29 77`. So it is the board, not one dead part, and the cross-check for a power measurement has to be a second *board*. 2. **With `gps duty` enabled you cannot measure anything under ~5 mA.** A sync window lands in a random cell and adds ~17 mA to a 10-minute average (seen: 40.9 mA against 24.1-24.5 in its neighbours). Put `gps off` in every cell of such a run and restore `gps duty` afterwards. See `tools/power_ab.py --help` for the alternating-cell design that makes these deltas trustworthy in the first place.