Boards own their FEM control through handleCommand() ("get/set
radio.fem.rxgain|txgain"). Use that instead of a parallel set of FEM
virtuals on MainBoard, so any board that implements the commands works
in KISS with no extra code.
- Remove the six FEM virtuals from MainBoard and the board overrides.
- KissModem talks to the board in one adapter. A gain counts as
controllable only if "get" replies exactly "> on" or "> off". "set"
is checked by reading the state back, never by its reply wording.
- SetFemState always replies with the read-back state once the
requested bits pass the capability check.
- Guard the boards' prefs writes against a NULL store. KISS attaches
no prefs, so "set radio.fem.*" would dereference NULL.
- Wio Tracker L1 1W TX gain is exposed again, matching its CLI.
37 lines
1003 B
C++
37 lines
1003 B
C++
#pragma once
|
|
|
|
#include <MeshCore.h>
|
|
#include <Arduino.h>
|
|
#include <helpers/NRF52Board.h>
|
|
#include <helpers/RefCountedDigitalPin.h>
|
|
#include <helpers/KeyValueStore.h>
|
|
#include "LoRaFEMControl.h"
|
|
|
|
class T096Board : public NRF52BoardDCDC {
|
|
KeyValueStore* _prefs = NULL;
|
|
|
|
protected:
|
|
#ifdef NRF52_POWER_MANAGEMENT
|
|
void initiateShutdown(uint8_t reason) override;
|
|
#endif
|
|
void variant_shutdown();
|
|
|
|
bool setLoRaFemLnaEnabled(bool enable);
|
|
bool isLoRaFemLnaEnabled() const;
|
|
|
|
public:
|
|
RefCountedDigitalPin periph_power;
|
|
LoRaFEMControl loRaFEMControl;
|
|
|
|
T096Board() :periph_power(PIN_VEXT_EN,PIN_VEXT_EN_ACTIVE), NRF52Board("T096_OTA") {}
|
|
void begin();
|
|
void attachDynamicPrefs(KeyValueStore* prefs);
|
|
bool handleCommand(const char* command, uint32_t sender_timestamp, char* reply) override;
|
|
|
|
void onBeforeTransmit(void) override;
|
|
void onAfterTransmit(void) override;
|
|
uint16_t getBattMilliVolts() override;
|
|
const char* getManufacturerName() const override ;
|
|
void powerOff() override;
|
|
};
|