Two upstream defaults that cost a headless solar node around the clock:
* Bluefruit blinks LED_BLUE while advertising and holds it on while connected.
On SenseCap Solar that pin is 12 -- the SAME pin as P_LORA_TX_LED -- so a
sealed mast node spends charge blinking an LED nobody can see, and the LoRa TX
indicator lies as a bonus. autoConnLed(false) by default (RPT_BLE_CONN_LED).
* The slow advertising interval sat at 244 units = 152.5 ms, i.e. three channels
~6.5 times a second for years. Now 1 s (RPT_BLE_ADV_SLOW); the first 30 s
after boot or a disconnect stay fast, so discovery is unaffected in practice.
Bench boards keep both upstream behaviours via platformio.local.ini: on a desk
the blinking LED is the "this board is alive" indicator.
Also: powersaving must not sleep while the BLE console still has queued output.
WFE only wakes on an interrupt, so a half-drained rxlog/pktlog page would sit in
the ring until the next connection event -- and on the observer node the bridge
drains those on a 2-minute duty cycle, where a slower drain directly costs
collected frames.
Measured: BLE (at the new interval, LED off) is ~1.3 mA of a ~24 mA node, so
`ble off` on a mast is not worth losing remote access over.