The BLE bridge drain was throttled by three multiplied costs: 150 B pages
(~3 rxlog records), 20 B NUS notification chunks, and the bridge waiting for
line silence per page. This fixes the firmware half:
- handleCommand() takes an explicit reply_max (default 150). The local console
(USB/BLE) passes ~1000 B -> ~20 rxlog records / ~7 nodes lines per round
trip; the mesh admin CLI keeps 150 so its reply still fits one LoRa packet.
Explicit parameter on purpose: a forged sender_timestamp==0 from the mesh
path must never be able to grow the reply past its 166 B buffer.
- bleWriteAll() chunks by negotiated MTU (247 -> 244 B) instead of fixed 20 B.
- Tables sized from channel physics instead of last week's traffic:
RXLOG_SIZE 512 = ~2 min of a saturated SF8/62.5k channel (~2-4 frames/s),
MAX_HEARD_NODES 128 > distinct nodes heard per neighbour advert period
(48 filled in <2 h and churned out real 0-hop neighbours).
- Page-sort scratch arrays moved off the loop-task stack into BSS.
RAM 17.7% -> 25.3% (59.6 KB / 235 KB). Flashed via BLE DFU 2026-07-15.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>