Repeater, room server, sensor, companion: build flag LOCKED_NODE for a node that keeps its secrets from whoever holds it

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
tthandClaude Opus 5.5 committed 2026-11-19 17:21:29 +01:00
1 parent 769139999d
commit b7249f449a
3 files changed
+26

No files matched your search

+1
View File
@@ -189,6 +189,7 @@ The ones that change what a node does; set in `platformio.ini` /
| `FW_OTA` | `-ota` images | admin-pushed firmware update |
| `PATH_HASH_MODE_DEFAULT` | `1` (2 B per hop) | path hash width for a node without prefs |
| `ACL_TS_MAX_AHEAD` | `86400` (s) | a client timestamp further ahead of the node's clock is not stored as the replay floor |
| `LOCKED_NODE` | unset | a node that keeps its secrets from whoever holds it: `get prv.key`, `get guest.password` and `get bridge.secret` answer `Error: locked build` to everyone (USB and BLE console, an admin over the mesh); a companion serves only paired BLE (USB, UART and WiFi get the device info and nothing else) and its rescue CLI refuses `set pin`. Only half of it: [locked-bootloader.md](locked-bootloader.md) |
| `LOGIN_FAIL_MAX`, `LOGIN_FAIL_SECS` | `4`, `180` (s) | after that many wrong passwords in the window no password is checked until it ends (an admin already in the ACL always gets in) |
Prefs saved on the node override the build defaults: a reflash keeps what a
+15
View File
@@ -1070,6 +1070,16 @@ void MyMesh::startInterface(BaseSerialInterface &serial) {
}
void MyMesh::handleCmdFrame(size_t len) {
#ifdef LOCKED_NODE
// CUSTOM (TeTeHacko): a locked companion serves only paired BLE. USB, a UART
// and WiFi/TCP get the device info (so an app sees what it talks to) and
// nothing else: no contacts, channels, messages or settings for whoever holds
// the board or sits on the LAN. docs/locked-bootloader.md, point 4.
if (!_serial->isConnectionSecure() && cmd_frame[0] != CMD_DEVICE_QUERY) {
writeDisabledFrame();
return;
}
#endif
if (cmd_frame[0] == CMD_DEVICE_QUERY && len >= 2) { // sent when app establishes connection
app_target_ver = cmd_frame[1]; // which version of protocol does app understand
@@ -2492,6 +2502,11 @@ void MyMesh::checkCLIRescueCmd() {
cli_command[len - 1] = 0; // replace newline with C string null terminator
reply_buf[0] = 0;
#ifdef LOCKED_NODE
if (memcmp(cli_command, "set pin ", 8) == 0) { // CUSTOM (TeTeHacko): a known PIN = pair and read it all
Serial.println(" Error: locked build");
} else
#endif
if (handleCommand(cli_command, 0, reply_buf)) {
// command was handled, print reply output
Serial.print(" "); Serial.print(reply_buf); Serial.println();
+10
View File
@@ -927,6 +927,16 @@ void CommonCLI::handleSetCmd(uint32_t sender_timestamp, char* command, char* rep
void CommonCLI::handleGetCmd(uint32_t sender_timestamp, char* command, char* reply) {
const char* config = &command[4];
#ifdef LOCKED_NODE
// CUSTOM (TeTeHacko): a locked node gives its secrets to nobody -- not to the
// USB console (no login: whoever holds the board), not to the BLE console, not
// to an admin over the mesh. docs/locked-bootloader.md, point 4.
if (memcmp(config, "prv.key", 7) == 0 || memcmp(config, "guest.password", 14) == 0 ||
memcmp(config, "bridge.secret", 13) == 0) {
strcpy(reply, "Error: locked build");
return;
}
#endif
if (memcmp(config, "allow.read.only", 15) == 0) {
sprintf(reply, "> %s", _prefs->allow_read_only ? "on" : "off");
} else if (memcmp(config, "flood.advert.interval", 21) == 0) {