power_ab.py --budka: wait out a short gap in the box's meter feed instead of dropping the run
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
f2dd7e8082
commit
ec55b7e8c3
1 file changed
+19
-10
+19
-10
@@ -59,17 +59,26 @@ def cbprom_sample(url, meter, device):
|
||||
one voltage held for the whole run: ~2 mAh at 5 V, twice the UC96's own step.
|
||||
"""
|
||||
global _cb_volts
|
||||
with urllib.request.urlopen(url, timeout=10) as r:
|
||||
body = r.read().decode()
|
||||
want = (f'device="{device}"', f'meter="{meter}"')
|
||||
out = {}
|
||||
for line in body.splitlines():
|
||||
if line.startswith("cb_meter_") and all(w in line for w in want):
|
||||
out[line.split("{", 1)[0]] = float(line.rsplit(" ", 1)[1])
|
||||
if "cb_meter_energy_wh" not in out or "cb_meter_voltage_volts" not in out:
|
||||
raise SystemExit(f"cbprom nema meter {meter} z budky {device}")
|
||||
age = time.time() - out.get("cb_meter_last_seen_timestamp_seconds", 0.0)
|
||||
if age > 30:
|
||||
# The box drops the meter for half a minute now and then (it killed a cell
|
||||
# 25 min in on 14. 11. 2026). A gap only thins the fitted series, so wait it
|
||||
# out; a feed that stays stale for minutes is a dead one.
|
||||
for attempt in range(25):
|
||||
with urllib.request.urlopen(url, timeout=10) as r:
|
||||
body = r.read().decode()
|
||||
out = {}
|
||||
for line in body.splitlines():
|
||||
if line.startswith("cb_meter_") and all(w in line for w in want):
|
||||
out[line.split("{", 1)[0]] = float(line.rsplit(" ", 1)[1])
|
||||
if "cb_meter_energy_wh" not in out or "cb_meter_voltage_volts" not in out:
|
||||
raise SystemExit(f"cbprom nema meter {meter} z budky {device}")
|
||||
age = time.time() - out.get("cb_meter_last_seen_timestamp_seconds", 0.0)
|
||||
if age <= 30:
|
||||
break
|
||||
if attempt == 0:
|
||||
print(f" (budka: posledni ramec pred {age:.0f} s, cekam)", flush=True)
|
||||
time.sleep(5)
|
||||
else:
|
||||
raise SystemExit(f"posledni ramec pred {age:.0f} s -- serie je zamrzla, ne stabilni")
|
||||
if _cb_volts is None:
|
||||
_cb_volts = out["cb_meter_voltage_volts"]
|
||||
|
||||
Reference in new issue