Repeaters, room servers and sensors already let the battery ADC multiplier be tuned with 'set adc.multiplier' (CommonCLI). The companion firmware had no equivalent, so a board whose divider differs from the build default (common on DIY ProMicro / Faketec boards) always reported a wrong battery voltage.
Adds the same command to the companion CLI. The value is stored in the companion prefs (comp.adc_mult, 0 = board default) and applied at startup via MainBoard::setAdcMultiplier().
CMD_SEND_CHANNEL_TXT_MSG reads txt_type, channel_idx and a 4 byte timestamp, so
the frame needs 7 bytes before the text starts, and the branch had no length
guard. For a shorter frame "len - i" is computed in size_t, wraps, and reaches
sendGroupMessage() as a negative int. The clamp there tests
"text_len + prefix_len > MAX_TEXT_LEN", which a negative value passes, and the
following memcpy() converts the length back to a size_t: a 3 byte frame asks for
4294967292 bytes into a 197 byte stack buffer.
Two guards, because there are two mistakes. The branch now states its minimum
like most other branches of handleCmdFrame do, so a frame below 7 bytes is
answered through the existing path instead of being parsed. And
sendGroupMessage() refuses a negative length the way sendGroupData() in the same
file already does, which protects every other caller.
A frame of exactly 7 bytes keeps working and sends an empty message, as before.
Evidence. On a T-Echo running dev c9fa617c, built with
FIRMWARE_BUILD_DATE "f1-dev" and confirmed by "ver => v1.18.0 (Build: f1-dev)":
CH_TXT len=7 -> RESP_CODE_OK
GET_STATS core -> uptime=78s
CH_TXT len=3 -> NO REPLY
DEVICE_QUERY -> NO REPLY (three times over 8 s, node never came back)
'get tz.offset' printed one decimal, so a UTC+5:45 offset (5.75)
read back as 5.8. Print two decimals when the offset is on a quarter
hour (x.25 / x.75); everything else keeps one decimal.
Payloads of 166 or 167 bytes previously passed the frame-sized bound
(MAX_CHANNEL_DATA_LENGTH = 167) but were rejected by sendGroupData
against MAX_GROUP_DATA_LENGTH (165), causing ERR_CODE_TABLE_FULL (retry
later) to be returned instead of ERR_CODE_ILLEGAL_ARG.
Fixes#3345
- scope the serial config CLI to RP2040; it was exposing the rescue CLI
(cat/rm/erase) on every ESP32 WiFi build, which gates it behind a
physical long-press
- bound and space out RP2040 rejoins: the core's join busy-waits, so cap
it at 5s and retry every 30s instead of every 10s
- stamp the reconnect timer in setup(), so the first loop() doesn't tear
down an association that is still finishing DHCP
- treat stored credentials as a pair, and pass NULL (not "") for an open
network
- teach build_as_lib.py where SerialWifiInterface moved
Store ssid/pwd in NodePrefs and set them with 'set wifi.ssid' /
'set wifi.pwd' over USB serial; build-time WIFI_SSID/WIFI_PWD stay as
the fallback. Headless WiFi builds get the config CLI on Serial, which
is otherwise unused there.